CyberPower Smart App Sinewave PR3000LCD - UPS - AC 120 V - 2700 Watt - 3000 VA 17 Ah - RS-232, USB - output connectors: 10 - active PFC

A tower UPS with line interactive topology, the CyberPower Smart App Sinewave PR3000LCD provides battery backup, power protection (using sine wave output), and surge protection for corporate servers, department servers, storage appliances, network devices, and telecom installations requiring Active PFC power source compatibility. The PR3000LCD uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently.

      Features

      Extendable LCD Control Panel

      Often a UPS is installed in a hard-to-reach area, such as a crowded IT closet, the bottom of a rack, or on the floor. A removable LCD control panel allows for easy access and can be placed up to ten feet away from the UPS when connected by a DB26 cable (sold separately).

      Menu Functions

      UPS Status displays vital information about the UPS. There are 19 status types, including input and output voltage, battery information, runtime estimates, load data, and more.

      LCD Settings Configuration offers customization of the UPS with 38 specific operation parameters including output voltage, sync frequency, alarm settings, and more.

      Event Log allows for recording of UPS events with or without PowerPanel® Business Edition management software.

      Multi-Language (select models) provides options to display text in English, Spanish, French, or German.

      Disable Audible Alarms turns off audible alarms, as needed.

      Manual Battery Test enables user to run a UPS system test to ensure proper operation.

       


      Efficient Remote Management

      The Smart App Series offers full-featured network UPS management capabilities with the PowerPanel® Business Edition software and an optional SNMP network management card. These remote management tools enable centralized power management, monitoring, control, and configuration. They also provide for safe shutdown of connected servers, workstations, and other devices via a standard Web browser or network management system (NMS).

      Safe Shutdown

      The PowerPanel® Business Edition software, included with every Smart App Sinewave UPS, enables an administrator to remotely manage each aspect of the UPS and facilitate the orderly automatic shutdown of connected equipment in the event of an extended power outage. This software also provides comprehensive network power management for corporate servers and critical workstations supported by the UPS, such as application/operating system shutdown, event logging, reporting, alerts and notifications.

      Programmable Outlet Control

      Smart App UPS systems allow programming of critical outlets and non-critical outlets, giving administrators the ability to prioritize outlets and increase battery backup runtimes for the most critical equipment during extended power outages. Programmable outlet control also gives an administrator the option to delay-start non-critical outlets, permitting the internal batteries to fully recharge more quickly. This feature is vital to data centers where seamless, uninterrupted equipment bootup is a necessity.

       


      GreenPower UPS Technology: Bypass Design

      GreenPower UPS™ Technology from CyberPower improves operating efficiency, reduce heat generation, and consume less power than conventional UPS models.

      Our patented Bypass Design allows current to bypass the transformer and automatic voltage regulation (AVR) when utility power is normal, thus reducing energy consumption and associated costs. Because utility power functions normally most of the time, the bypass design allows for substantial energy savings. This technology also reduces heat generation, an important factor in decreasing operating costs.


      Sine Wave Power

      In the U.S., utility companies provide power to households and offices by distributing single phase alternating current (AC) power at a frequency of 60 Hz. Electrical power can be graphically depicted as a sine wave whereby the electrical signal alternates from +120 volts to -120 volts at a rate of 60 times per second (60 Hz). To enable more efficient operation of large, heavy equipment, utility companies provide commercial and industrial locations with three phase AC power which consists of three overlapping sine waves offset by 120 degrees.

      Although utility companies strive to distribute 100% sine wave power, many factors can introduce electrical noise into the AC power signal in the form of sine wave distortions and as voltage sags, surges, spikes, or other irregularities. Sine wave power is important for the optimal functioning of sensitive desktop computers and related peripheral equipment. Without sine wave power output, microprocessor-based equipment can become inoperative or sustain damage from power signal distortions.

       


      Active Power Factor Correction Supplies for IT Equipment

      During the past thirty years, people have become more aware of the amount of energy used by IT equipment and devices. For many years, desktop computers and workstations inefficiently consumed power, partly due to the design of the power supplies which transformed AC power (from the wall outlet) to DC power (used by computers). This voltage transformation was relatively inefficient as reflected in low power factor ratings.

      In 1992, the U.S. Environmental Protection Agency (EPA), in collaboration with advocates in the IT industry, developed the ENERGY STAR® program to prompt the development of energy-efficient products. Today this program is recognized as an international standard.

      To comply with ENERGY STAR standards, manufacturers of desktop and workstation computers incorporate Active Power Factor Correction (Active PFC) as part of the engineering designs, enabling energy efficiencies of 95% or higher. Computers with Active PFC power supplies require sine wave AC power, as supplied by utility companies, for trouble-free operation. For this reason, sine wave UPS systems have become the best choice for backup power.

      Simulated or stepped sine wave power, provided by entry-level UPS systems, may be problematic or incompatible with Active PFC devices. Sine wave power varies continuously from positive to negative. Simulated sine wave power mimics a sine wave by using a squared-off approximation. Due to this approximation, simulated sine wave power momentarily creates a zero power gap. When power is interrupted, a computer with an Active PFC power supply may not recognize incoming simulated sine wave power due to the zero output present in the approximated wave. This could cause the system to unexpectedly shut down or sustain system component stress.

      Spec's

      MAIN SPECIFICATIONS

      Product Description CyberPower Smart App Sinewave PR2200LCD - UPS - 1980 Watt - 2200 VA
      Device Type UPS - active Power Factor Correction (PFC) - external
      Weight 115.96 lbs
      Input Voltage AC 120 V
      Output Voltage AC 120 V + 5% / - 5%
      Power Capacity 1980 Watt / 2200 VA
      Input Connectors 1 x power NEMA L5-30
      Output connectors 8 x power NEMA 5-15 (UPS and surge) ¦ 2 x power NEMA 5-20 (UPS and surge)
      Battery Lead acid - 17 Ah
      Batteries Qty 4
      Run Time (Up To) 8 min at full load
      Networking RS-232, USB
      Dimensions (WxDxH) 7.7 in x 20.2 in x 17 in
      Manufacturer Warranty 3 years warranty

      EXTENDED SPECIFICATIONS

      General
      Device Type UPS - active Power Factor Correction (PFC) - external
      Power Device
      UPS Technology Line interactive
      Input Voltage AC 120 V
      Input Voltage Range AC 75 - 154 V
      Frequency Provided 50/60 Hz
      Frequency Required 47 - 63 Hz
      Input Connectors 1 x power NEMA L5-30
      Power Output Connectors Details 8 x power NEMA 5-15 (UPS and surge) ¦ 2 x power NEMA 5-20 (UPS and surge)
      Output Voltage AC 120 V + 5% / - 5% - 50/60 Hz
      Power Capacity 1980 Watt / 2200 VA
      Output Waveform Sinewave
      Surge Suppression Yes
      Surge Energy Rating 1030 Joules
      Circuit Protection Circuit breaker
      Battery
      Quantity 4
      Technology Lead acid
      Voltage Provided 12 V
      Capacity 17 Ah
      Run Time (Up To) 8 min at full load ¦ 26 min at half load
      Recharge Time 8 hours
      Switchover Time 4 ms
      Networking
      Remote Management Interface RS-232, USB
      Expansion / Connectivity
      Interfaces 1 x RS-232 - 9 pin D-Sub (DB-9) ¦ 1 x USB - 4 pin USB Type B ¦ 1 x EPO (emergency power off)
      Miscellaneous
      Cables Included Power cable - 10 ft ¦ USB cable - external ¦ Serial cable - external ¦ EPO cable - external
      Equipment Protection Value 375000 US Dollars
      Features Active Power Factor Correction (PFC), audible alarm, emergency power off, LCD display, Automatic Voltage Regulation (AVR), GreenPower UPS Technology, noise filtering, overload protection
      Compliant Standards cUL, DOC-B, UL 1778, FCC, RoHS, CSA C22.2 No. 107.3
      Software / System Requirements
      Software Included PowerPanel Business Edition
      Manufacturer Warranty
      Service & Support Limited warranty - 3 years
      Environmental Parameters
      Min Operating Temperature 32 °F
      Max Operating Temperature 104 °F
      Humidity Range Operating 0 - 90% (non-condensing)
      Dimensions & Weight
      Width 7.7 in
      Depth 20.2 in
      Height 17 in
      Weight 115.96 lbs