Menu
Cart 0

CyberPower 3KVA High Voltage Online UPS OL3000RTXL2UHV

CyberPower

  • $ 1,34995


CyberPower Smart App Online OL3000RTXL2UHV - UPS - AC 200-240 V - 2.7 kW - 3000 VA 9 Ah - RS-232, USB - output connectors: 3 - 2U

A rack/tower UPS with double conversion topology, the CyberPower Smart App Online OL3000RTXL2UHV provides sine wave output to mission-critical applications and equipment requiring seamless power protection. This model comes with an extendable LCD control panel, Smart Battery Management charging technology, and energy-saving GreenPower UPS ECO Mode.

The OL3000RTXL2HV offers generator compatibility and delivers clean AC power with zero transfer time. This model can use the BP72V60ART2U Extended Battery Module for expanded runtime and faster restoration of full backup power with Fast Charge Technology.

  • 3000VA / 2700W High Voltage UPS System, 200-240VAC input and output
  • Double Conversion Topology / Sine Wave Output
  • 2U Rack Mount / Tower Convertible
  • Extended runtime options / Smart Battery Management
  • 3 Outlets / USB, Serial, Relay Contacts, and EPO Ports
  • Generator Compatible

FREE SHIPPING!

    Battery Technology

    Fast Charge Technology and Smart Battery Management (SBM) prolong the capacity and life of a UPS battery. This provides greater efficiency and fewer battery replacements.

    Fast Charge Technology enables the backup power supply to more quickly return to full capacity (100%) because each Extended Battery Module attached to the UPS uses its own charger. Typical systems share only a single charger for all attached battery modules, which increases the time required to fully restore backup power.

    Smart Battery Management (SBM) charges a UPS battery in three phases, extending its functional life. SBM also reduces the heat produced by a UPS battery and reduces battery deterioration.

     


    Extendable LCD Control Panel

    Often a UPS is installed in a hard-to-reach area, such as a crowded IT closet, the bottom of a rack, or on the floor. A removable LCD control panel allows for easy access and can be placed up to ten feet away from the UPS when connected by a DB26 cable (sold separately).

    Menu Functions

    UPS Status displays vital information about the UPS. There are 19 status types, including input and output voltage, battery information, runtime estimates, load data, and more.

    LCD Settings Configuration offers customization of the UPS with 38 specific operation parameters including output voltage, sync frequency, alarm settings, and more.

    Event Log allows for recording of UPS events with or without PowerPanel® Business Edition management software.

    Multi-Language (select models) provides options to display text in English, Spanish, French, or German.

    Disable Audible Alarms turns off audible alarms, as needed.

    Manual Battery Test enables user to run a UPS system test to ensure proper operation.

     


    Higher Capacity UPS for Longer Runtimes

    To determine the size of the UPS that you need, identify the total power load (measure in VA/Watts) of the connected equipment, along with the amount of runtime required (in minutes). Also, think about any equipment that might be connected to the UPS in the future, which could affect the calculations for load and runtime.

    Estimating expected UPS runtimes can be challenging, particularly when the consistency of the utility power is not well known. Selecting a UPS with a load capacity 30-35% above the required power load offers the advantage of longer runtimes. This can lower the risk of overloading the UPS and causing an unnecessary UPS shutdown.

    Although the initial outlay of a UPS increases with its size because of the higher capacity required for components, long-term operating costs typically decrease. When a UPS operates below maximum capacity, it reduces the stress on components. Sizing a UPS to run loads significantly lower than its capacity also increases spare capacity for future growth, along with extending runtimes.

     


    Efficient Remote Management

    The Smart App Series offers full-featured network UPS management capabilities with the PowerPanel® Business Edition software and an optional SNMP network management card. These remote management tools enable centralized power management, monitoring, control, and configuration. They also provide for safe shutdown of connected servers, workstations, and other devices via a standard Web browser or network management system (NMS).

    Safe Shutdown

    The PowerPanel® Business Edition software, included with every Smart App Sinewave UPS, enables an administrator to remotely manage each aspect of the UPS and facilitate the orderly automatic shutdown of connected equipment in the event of an extended power outage. This software also provides comprehensive network power management for corporate servers and critical workstations supported by the UPS, such as application/operating system shutdown, event logging, reporting, alerts and notifications.

    Programmable Outlet Control

    Smart App UPS systems allow programming of critical outlets and non-critical outlets, giving administrators the ability to prioritize outlets and increase battery backup runtimes for the most critical equipment during extended power outages. Programmable outlet control also gives an administrator the option to delay-start non-critical outlets, permitting the internal batteries to fully recharge more quickly. This feature is vital to data centers where seamless, uninterrupted equipment bootup is a necessity.

     


    Sine Wave Power

    In the U.S., utility companies provide power to households and offices by distributing single phase alternating current (AC) power at a frequency of 60 Hz. Electrical power can be graphically depicted as a sine wave whereby the electrical signal alternates from +120 volts to -120 volts at a rate of 60 times per second (60 Hz). To enable more efficient operation of large, heavy equipment, utility companies provide commercial and industrial locations with three phase AC power which consists of three overlapping sine waves offset by 120 degrees.

    Although utility companies strive to distribute 100% sine wave power, many factors can introduce electrical noise into the AC power signal in the form of sine wave distortions and as voltage sags, surges, spikes, or other irregularities. Sine wave power is important for the optimal functioning of sensitive desktop computers and related peripheral equipment. Without sine wave power output, microprocessor-based equipment can become inoperative or sustain damage from power signal distortions.

     


    Active Power Factor Correction Supplies for IT Equipment

    During the past thirty years, people have become more aware of the amount of energy used by IT equipment and devices. For many years, desktop computers and workstations inefficiently consumed power, partly due to the design of the power supplies which transformed AC power (from the wall outlet) to DC power (used by computers). This voltage transformation was relatively inefficient as reflected in low power factor ratings.

    In 1992, the U.S. Environmental Protection Agency (EPA), in collaboration with advocates in the IT industry, developed the ENERGY STAR® program to prompt the development of energy-efficient products. Today this program is recognized as an international standard.

    To comply with ENERGY STAR standards, manufacturers of desktop and workstation computers incorporate Active Power Factor Correction (Active PFC) as part of the engineering designs, enabling energy efficiencies of 95% or higher. Computers with Active PFC power supplies require sine wave AC power, as supplied by utility companies, for trouble-free operation. For this reason, sine wave UPS systems have become the best choice for backup power.

    Simulated or stepped sine wave power, provided by entry-level UPS systems, may be problematic or incompatible with Active PFC devices. Sine wave power varies continuously from positive to negative. Simulated sine wave power mimics a sine wave by using a squared-off approximation. Due to this approximation, simulated sine wave power momentarily creates a zero power gap. When power is interrupted, a computer with an Active PFC power supply may not recognize incoming simulated sine wave power due to the zero output present in the approximated wave. This could cause the system to unexpectedly shut down or sustain system component stress.

     


    GreenPower UPS Technology: Eco Mode

    GreenPower UPS™ Technology from CyberPower improves operating efficiency, reduce heat generation, and consume less power than conventional UPS models.

    ECO Mode is a form of bypass technology that can be switched on full time, set for noncritical times (such as nights and weekends), or switched off. This flexibility can help conserve power and save money.

    MAIN SPECIFICATIONS

    UPS Topology Double-Conversion
    Energy Saving Yes – ECO Mode Efficiency >97%
    ENRGY STAR® Qualified Yes
    Input
    Voltage 200 – 240 VAC
    Input Voltage Range 120 – 139 VAC for 0–60% load

     

    140 – 159 VAC for 0–70% load

    160 – 179 VAC for 0–80% load

    180 – 189 VAC for 0–90% load

    190 – 280 VAC for 0–100% load

    Frequency Range 40 – 70 Hz (auto-sensing)
    Input Power Factor 0.99
    Cold Start Yes
    Plug Type NEMA L6-20P
    Cord Length 10 ft
    Output
    VA 3,000 VA
    Watts 2,700 W
    On Battery Voltage 200, 208, 220, 230, 240 VAC (Configurable) ± 2%
    On Battery Frequency 50/60 Hz ± 0.25 Hz (auto-sensing or configurable)
    On Battery Waveform Sine Wave
    Outlet Type NEMA L6-20R (2), NEMA L6-30R (1)
    Outlets – Total 3
    Rated Power Factor 0.9
    Crest Factor 3:1
    Harmonic Distortion THD < 3% at Linear Load, < 5% at Non-linear Load
    ECO Mode Voltage Regulation ±10%, ±15% (Configurable)
    Bypass Internal Bypass (Automatic and Manual)
    Overload Protection Line Mode:

     

    105~125% Load for 1 min

    126~150% Load for 10 sec

    Battery Mode:

    105~130% Load for 10 sec

    131~150% Load for 2 sec

    Transfer Time 0 ms
    Battery
    Runtime at Half Load 11 minutes
    Runtime at Full Load 4 minutes
    Battery Type Sealed Lead-Acid
    Battery Size 12V/9Ah
    Battery Quantity 6
    Hot-Swappable Yes
    User Replaceable Yes
    Replacement Battery Cartridge RB1290X6A
    Replacement Battery Cartridge Quantity 1
    Typical Recharge Time 4 hours
    Extended Battery Option BP72V60ART2U
    Smart Battery Management (SBM) Mode Yes
    Surge Protection & Filtering
    Surge Suppression 1335 Joules, IEC 61000-4-5 Level 3
    EMI/RFI Filter Yes
    Phone / Network Protection RJ11/RJ45 1-In / 1-Out
    Management & Communications
    LCD Control Panel Access 42 information status and configuration settings via the Information and Configuration Menus, in addition to an Event Log Menu.
    Rotatable LCD Control Panel Option Yes
    Extendable LCD Control Panel Option Yes – Requires a separate DB26 Cable
    HID Compliant USB Port Yes
    Serial Port Yes
    EPO Port Yes
    Dry Contacts Yes
    Management Cable USB Cable, Serial Cable, Phone Cable
    LED Indicators Power On (white)

     

    Line Mode (green)

    Battery Mode (yellow)

    Bypass Mode (yellow)

    Fault (red)

    Replace Battery (red)

    Audible Alarms Battery Mode

     

    Battery Low

    Overload

    UPS Fault

    Software PowerPanel® Business Edition
    Expasion Slot Yes – Optional RMCARD205 or RELAYIO500
    Physical
    Rack Size 2U
    Form Factor Rack/Tower
    Enclosure Contruction Steel
    Mounting Hardware Included
    Dimensions – W×H×D (in) 17 × 3.5 × 23.62 inches
    Dimensions – W×H×D (mm) 433 × 88 × 600 mm
    Weight (lbs) 68.2 lbs
    Weight (kg) 31 kg
    Shipping Dimensions – W×H×D (in) 23.23 × 9.45 × 35.04 inches
    Shipping Dimensions – W×H×D (mm) 590 × 240 × 890 mm
    Shipping Weight (lbs) 86.9 lbs
    Shipping Weight (kg) 39.4 kg
    Environmental
    Operating Temperature 32 – 104 °F (0 – 40 °C)
    Operating Humidity 0 – 90% (non-condensing)
    Operating Elevation 0 – 10,000 ft (0 – 3,000 m)
    Storage Temperature -4 – 113 °F (-20 – 45 °C)
    Storage Relative Humidity 0 – 95% (non-condensing)
    Storage Elevation 0 – 50,000 ft (0 – 15,000 m)
    Online Thermal Dissipation 845 BTU/hr
    Audible noise at 1.5M from surface of unit < 50 dBA
    Certifications
    Safety UL1778

     

    CSA C22.2 NO.107.3-05

    FCC DOC Class A

    Environmental RoHS Compliant
    Warranty
    Product Warranty 3 Years Limited
    Connected Equipment Guarantee Lifetime
    CEG Amount $400,000

    Founded in 1997, Cyber Power Systems (USA), Inc., designs and manufactures a high quality line of award-winning products, including uninterruptible power supply (UPS) systems, power distribution units (PDUs), surge protectors, mobile charging devices, connectivity devices and Fiber-to-the-Premise (FTTx) backup power solutions. Meeting the growing power needs of businesses and people has helped our organization achieve worldwide success. As a true manufacturer, we are driven by a mission to deliver the highest standard of product quality, performance, and customer value in the industry.